Darks

Can old darks be used, if not why ?  

How often do a set of darks need to be replaced ?

For spectra reduction, are the same number of darks required as spectra ? 

Regards,

Jack 

Peter Carson's picture
Offline
Last seen: 7 hours 3 min ago
Joined: 06/04/2014 - 20:41
Caloibration frame re use

Hi Jack,

I built up a library of dark, bias and flat frames for my CCD camera that I reused many times over. Provided your light  and dark images are taken at the same camera temperature and duration then darks and bias images can be reused for a long period. I refreshed my library about every year, not that I needed to but just thought I ought to. Flat frames can be reused provided the focus position remains the same and the camera has not been re-orientated or moved in any other way.

I've just moved on to a CMOS camera and am re using the darks and flats. Does any have an opinion about the re use of CMOS calibration frames?

Peter

Robin Leadbeater's picture
Offline
Last seen: 2 hours 45 min ago
Joined: 05/03/2014 - 00:50
changes in darks

I don't have any experience with CMOS (yet) but with my CCD cameras I redo them every few months. Bias frames take no time at all but getting enough  long exposure darks eg 1200 sec can take all night so I just leave the camera running  on a cloudy night. I then produce a defect map from these and scale the master darks depending on exposure. I find the only significant changes have been with hot and warm pixels (and with one camera a faint line defect appeared) These are not a disaster as a cosmics removal tool normally zaps them but it is better if they can be fixed at source using an up to date defect map

With spectroscopic flats it is important to redo them if you move the wavelength range. I normally do them for each observation with the LHIRES and once a night with the ALPY. it takes little time with the built in calibration units though the results with the LHIRES at the blue end are very suspect due to light leaking past the slit.

I aim to sum at least 20 exposures (30 for ALPY flats where the light level is very low at the blue end)

Cheers

Robin

Robin Leadbeater's picture
Offline
Last seen: 2 hours 45 min ago
Joined: 05/03/2014 - 00:50
rogue warm pixels

An interesting example has just popped up showing the problems a rogue warm pixel can cause

https://britastro.org/node/23983

jack martin's picture
Offline
Last seen: 1 week 10 hours ago
Joined: 20/01/2017 - 12:41
Peter and Robin,

Peter and Robin,

Thanks for your advices, very helpful.

Regards,

Jack